276°
Posted 20 hours ago

New Improved NeuroTrac Continence Pelvic Floor Muscle (Kegel) Stimulator

£9.9£99Clearance
ZTS2023's avatar
Shared by
ZTS2023
Joined in 2023
82
63

About this deal

NeuroTrac ® Continence can be used externally with surface electrodes ( Adhesive TENS electrodes square 5cmx5cm / Adhesive TENS electrodes round 3cm ), or internally with vaginal electrodes ( PERIFORM Vaginal Electrode ) or anal electrodes ( PFLEX Anal Probe PR-13 ). If the battery voltage is below 6.6 (+/- 0.2) volts the unit will not turn on. Physical dimensions: 119.2 x 69 x 28.7 mm Weight: 0.07KG without battery, 0.1KG with battery. Environmental Conditions for use: Amplitude: 0 - 90 mA into 500 Ohm load; indication only. Actual mA will tend to be less than indicated due to electrode impedance: at 1000 Ohms load (Electrodes in poor condition) the maximum will be limited to 70 mA, at 1500 Ohms load the maximum will be limited to 65 mA.

Digital Dual Channel Stimulator (NMES)used to treat urinary incontinence by sending a mild electric current to the pelvic floor muscles using a probe.The unit comes with 2 lead wires, a 9v battery, a handy carry case and the full NeuroTrac® Continence Operators Manual . What do I get? The NeuroTrac PelviTone unit comes with the Kegel8 Comfort Probe for vaginal exercise and 2 lead wires , 9v battery, a handy carry case and the full NeuroTrac Continence Operators Manual; everything you need to get started!

Amplitude: 0-90 mA into 500 Ohm load; actual mA will tend to be less than indicated due to electrode impedance: at 1000 Ohms load (Electrodes in poor condition) the maximum will be limited to 86 mA, at 1500 Ohms load the maximum will be limited to 65 mA. Specifications: Dual channel: individually isolated circuits. Amplitude: 0-90 mA into 500 Ohm load; actual mA will tend to be less than indicated due to electrode impedance: at 1000 Ohms load (Electrodes in poor condition) the maximum will be limited to 86 mA, at 1500 Ohms load the maximum will be limited to 65 mA. Type: Constant current, maximum output voltage 180 Volts +10 / -30 Volts. Waveform: Symmetrical, rectangular bi-phasic with zero DC current. Selectable pulse width: 50 μS – 330 μS [2% accuracy]. Pulse Rate selection: in the continuous mode 2 – 100 Hz [2% accuracy]. Time duration of the treatment selectable: 1 minute to 90 minutes. Low Battery Indicator: If the battery goes below 6.9 volts +/- 0.2 volts the battery symbol will flash on/off once every second. Open Electrode Detect: If an open circuit is detected at the output of channel A or B the output current will be reset at zero. Ramp up time: 0.1-9.9 seconds. If the battery voltage is below 6.6 (+/- 0.2) volts the unit will not turn on. Advanced multi-phase programmes are programmed into this machine where treatment is split into time phases with different stimulation parameters. The NeuroTrac PelviTone uses neuromuscular electrical stimulation (NMES) to trigger your muscles into action. It has all of the same features as the NeuroTrac Continence, as well as advanced multi-phase programmes where treatment is split into time phases with different stimulation parameters and stronger symmetrical stimulation with the reduced Pulse Width: 50 – 330 μS. You have had any form of bladder/incontinence surgery, particularly if mesh was inserted (you need to discuss it with your GP first)Dual channel: individually isolated circuits. Amplitude: 0 - 90 mA into 500 Ohm load; indication only. Actual mA will tend to be less than indicated due to electrode impedance: at 1000 Ohms load (Electrodes in poor condition) the maximum will be limited to 70 mA, at 1500 Ohms load the maximum will be limited to 65 mA. Type: Constant Current, maximum output voltage 180 Volts +10 / -30 Volts Waveform: Asymmetrical, rectangular bi-phasic with zero DC current. Selectable pulse width: 50 μS - 450 μS [2% accuracy]. Pulse Rate selection: in the continuous mode 2 Hz - 100 Hz [2% accuracy]. Time duration of the treatment selectable: 1 minute to 90 minutes. Low Battery Indicator: If the battery goes below 6.9 volts +/- 0.2 volts the battery symbol will flash on/off once every second. Open Electrode Detect: If an open circuit is detected at the output of channel A or B the output current will be reset at zero. Ramp up time: 0.3 - 9.9 seconds. If the battery voltage is below 6.6 (+/- 0.2) volts the unit will not turn on. To strengthenpelvic floor muscles - use the 'stress' programs : PO3, PO4, or 'building up endurance' PO9 The NeuroTrac Continence unit comes with the VeriProbe which is suitable to use vaginally or anally, making this device suitable for both men and women and for treating both urinary and faecal incontinence. Plus it has two channels which can be controlled independently so that you can use a 3-electrode probe if you wish, or you can use both an anal and vaginal probe together at the same time for a more complete pelvic floor workout. Also included is a 9v battery, a handy carry case and the full NeuroTrac Continence Operators Manual; everything you need to get started!

Asda Great Deal

Free UK shipping. 15 day free returns.
Community Updates
*So you can easily identify outgoing links on our site, we've marked them with an "*" symbol. Links on our site are monetised, but this never affects which deals get posted. Find more info in our FAQs and About Us page.
New Comment